Sunday, January 10, 2010

Fire Press Two fer

ISSUING OFFICER: Dave Haworth/ Battalion Chief
DATE OF INCIDENT: 1/9/2010
INCIDENT TYPE: Structure Fire
INCIDENT ADDRESS: 1712 W Nora Ave
CITY: Spokane
STATE: Wa
ZIP:

NARRATIVE: On 01/09/2010 at 1409 hours, the Spokane Fire Department responded 3 engines, 3 ladders, 1 pumper-ladder, and 2 battalion chiefs to a reported structure fire at 1712 W Nora Ave. First arriving company, SE3, reported heavy smoke coming from a 2 story residential structure. The first arriving ladder company was assigned to search the structure for occupants while other companies began a coordinated attack on the fire, which was located on the first floor and the basement. The basement location presented a challenge due to the fact there was no access for fire attack companies or windows to remove smoke. Companies had to manually create openings to expose and extinguish the fire. There were no injuries to civilians and one firefighter received a minor laceration to his hand.

PROBABLE CAUSE: This fire is under investigation by the Spokane Fire Department Special Investigative Unit.
DAMAGE EXTENT: Heat damage was confined to the basement and the first floor with smoke damage throughout the rest of the structure.
DOLLAR LOSS:
FIREFIGHTER RESPONSE: 28
MUTUAL AID: None Given

For more information on this release, please call (509)625-7002 and/or check out the SFD Blog at www.spokanefire.blogspot.com

END OF RELEASE




ISSUING OFFICER: Dave Haworth/Battalion Chief
DATE OF INCIDENT: 1/9/2010
INCIDENT TYPE: Structure Fire
INCIDENT ADDRESS: 2311 N Stevens St
CITY: Spokane
STATE:
ZIP:

NARRATIVE: On 01/09/2010 at 1110 hours, the Spokane Fire Department responded 3 engines, 2 ladders, 1 pumper-ladder, and 2 battalion chiefs to a reported structure fire at 2311 N Stevens. First arriving SE3 reported smoke coming from the structure. After ensuring all occupants were out, companies began a coordinated attack on the fire which was located in the basement. Basement fires present a unique challenge to firefighters due to the fact they can be very hard to access, difficult to ventilate, and have the potential to extend vertically throughout the structure. Companies had to remove a large portion of the first floor to finally expose and extinguish the fire.

PROBABLE CAUSE: The Spokane Fire Department Special Investigative Unit determined that the fire was caused by a space heater which was placed in a crawl space under the first floor to keep water pipes from freezing. The heater ignited wood framing under the floor.
DAMAGE EXTENT: Heat damage was confined to the basement and first floor with smoke damage throughout the rest of the structure.
DOLLAR LOSS:
FIREFIGHTER RESPONSE: 24
MUTUAL AID: None Given

For more information on this release, please call (509)625-7002 and/or check out the SFD Blog at www.spokanefire.blogspot.com

END OF RELEASE

2 comments:

Anonymous said...

Good day, sun shines!
There have been times of troubles when I didn't know about opportunities of getting high yields on investments. I was a dump and downright pessimistic person.
I have never imagined that there weren't any need in large starting capital.
Nowadays, I feel good, I begin to get real money.
It gets down to select a proper partner who uses your funds in a right way - that is incorporate it in real deals, parts and divides the income with me.

You can ask, if there are such firms? I have to answer the truth, YES, there are. Please be informed of one of them:
http://theblogmoney.com

tonyb said...

Insurance policyholders can fend for themselves after a disaster: www.DisasterPrepared.net/whitehouse.html

What does anyone expect in case of loss (hurricane, tornado, earthquake,
flood, fire, etc.)?
The disaster itself is news. What happens after the dust settles is the
real story.
Perhaps insurance policyholders need to know they can have access to basic
rights and information? No way.

Way: www.DisasterPrepared.net